1. Typical efficiency
6W,Extremely-Huge Voltage Enter, Remoted Regulated Single/Twin, DIP Package deal
DC-DC Energy Module
-
Huge enter voltage vary(4:1),Output 6W
-
Conversion efficiency91%(Typ)
-
Isolation voltage 1500Vdc
-
Extremely-low standby energy
consumption:0.036W
(typical worth)
-
Tremendous quick startup:1mS(typical worth)
-
Working temperature vary:-40°C~+85°C
-
Enter undervoltage, output brief circuit, overcurrent, overvoltage safety
-
Metallic case, low output ripple
-
Worldwide commonplace pins, PCB board in-line
set up
HLK-URB24_YMD-6WR3 collection product output energy is 6W, 4:1 large voltage enter vary, effectivity as much as 91%, typical isolation voltage of 1500VDC, allowable working temperature -40℃ to +85℃, with Enter under-voltage safety, output over-voltage, over-current, short-circuit safety capabilities, naked metallic meets CISPR32/EN55032 CLASS A, broadly utilized in medical, industrial management, electrical energy, instrumentation, communication, railway and different fields.
2. Product Coding Guidelines
3. Product Mode Checklist
Product Mode① |
Enter Voltage vary (Vdc) |
Output Voltage/Present |
Ripple and Noise |
Most capacitive load |
Effectivity @ full load |
|||
Nominal value② (vary worth) |
Max |
Output voltage (Vdc) |
Output present(mA)(Max.Min.) |
Full load(mVp-p) (TPY/Max.) |
μF Max. |
% (Min/TPY) |
||
URB2403YMD-6WR3 |
24 (9-36) |
40 |
3.3 |
1400/0 |
30/50 |
2500 |
80/82 |
|
URB2405YMD-6WR3 |
5 |
1200/0 |
30/50 |
2200 |
83/85 |
|||
URB2412YMD-6WR3 |
12 |
500/0 |
50/80 |
680 |
87/89 |
|||
URB2415YMD-6WR3 |
15 |
400/0 |
50/80 |
470 |
88/90 |
|||
URB2424YMD-6WR3 |
24 |
250/0 |
50/80 |
220 |
89/91 |
|||
URA2405YMD-6WR3 |
±5 |
±600/0 |
30/50 |
1100 |
83/85 |
|||
URA2412YMD-6WR3 |
±12 |
±250/0 |
50/80 |
330 |
86/88 |
|||
URA2415YMD-6WR3 |
±15 |
±200/0 |
50/80 |
220 |
88/90 |
|||
URA2424YMD-6WR3 |
±24 |
±125/0 |
50/80 |
100 |
89/91 |
|||
URB4803YMD-6WR3 |
48 (18-75) |
80 |
3.3 |
1400/0 |
30/50 |
2500 |
80/82 |
|
URB4805YMD-6WR3 |
5 |
1200/0 |
30/50 |
2200 |
83/85 |
|||
URB4812YMD-6WR3 |
12 |
500/0 |
50/80 |
680 |
87/89 |
|||
URB4815YMD-6WR3 |
15 |
400/0 |
50/80 |
470 |
88/90 |
|||
URB4824YMD-6WR3 |
24 |
250/0 |
50/80 |
220 |
89/91 |
|||
URA4805YMD-6WR3 |
±5 |
±600/0 |
30/50 |
1100 |
83/85 |
|||
URA4812YMD-6WR3 |
±12 |
±250/0 |
50/80 |
330 |
86/88 |
|||
URA4815YMD-6WR3 |
±15 |
±200/0 |
50/80 |
220 |
88/90 |
|||
URA4824YMD-6WR3 |
±24 |
±125/0 |
50/80 |
100 |
89/91 |
|||
URB11003YMD-6WR3 |
110 (40-160) |
180 |
3.3 |
1400/0 |
30/50 |
2500 |
80/82 |
|
URB11005YMD-6WR3 |
5 |
1200/0 |
30/50 |
2200 |
83/85 |
|||
URB11012YMD-6WR3 |
12 |
500/0 |
50/80 |
680 |
87/89 |
|||
URB11015YMD-6WR3 |
15 |
400/0 |
50/80 |
470 |
88/90 |
|||
URB11024YMD-6WR3 |
24 |
250/0 |
50/80 |
220 |
89/91 |
|||
URA11005YMD-6WR3 |
±5 |
±600/0 |
30/50 |
1100 |
83/85 |
|||
URA11012YMD-6WR3 |
±12 |
±250/0 |
50/80 |
330 |
86/88 |
|||
URA11015YMD-6WR3 |
±15 |
±200/0 |
50/80 |
220 |
88/90 |
|||
URA11024YMD-6WR3 |
±24 |
±125/0 |
50/80 |
100 |
89/91 |
|||
Be aware: 1. Resulting from restricted house, the above is only a checklist of typical merchandise. Should you want merchandise apart from the checklist, please contact the gross sales division of our firm. 2. The utmost capacitive load signifies the utmost capacitive load that may be linked to +Vo or -Vo. If it exceeds this worth, the product won’t be able to start out usually. |
||||||||
Take a look at situations: With out specifiedwants, all parameter checks are measured at nominal enter voltage, purely resistive rated load and 25°C room temperature. |
4. Enter Traits
5. Output Traits
Our Firm