Free Shipping Mini 2pcs 6W 24V To 5V DC DC Converter Smart Home Isolated Power Supply Module Consumer Electronics
Worth: [price_with_discount]
1. Typical effectivity
6W,Extraordinarily-Intensive Voltage Enter, Isolated Regulated Single/Twin, DIP Bundle DC-DC Vitality Module
-
Intensive enter voltage differ(4:1),Output 6W
-
Conversion efficiency91%(Typ)
-
Isolation voltage 1500Vdc
-
Extraordinarily-low standby vitality consumption:0.036W(typical price)
-
Super fast startup:1mS (typical price)
-
Working temperature differ:-40°C~+85°C
-
Enter undervoltage, output transient circuit, overcurrent, overvoltage security
-
Metallic case, low output ripple
-
Worldwide commonplace pins, PCB board in-line arrange
HLK-URB24_YMD-6WR3 sequence product output vitality is 6W, 4:1 broad voltage enter differ, effectivity as a lot as 91%, typical isolation voltage of 1500VDC, allowable working temperature -40℃ to +85℃, with Enter under-voltage security, output over-voltage, over-current, short-circuit security options, bare metallic meets CISPR32/EN55032 CLASS A, also used in medical, industrial administration, electrical vitality, instrumentation, communication, railway and completely different fields.
2. Product Coding Pointers
3. Product Mode Document
Product Mode① |
Enter Voltage differ (Vdc) |
Output Voltage/Current |
Ripple and Noise |
Most capacitive load |
Effectivity @ full load |
|||
Nominal value② (differ price) |
Max |
Output voltage (Vdc) |
Output current(mA)(Max.Min.) |
Full load(mVp-p) (TPY/Max.) |
μF Max. |
% (Min/TPY) |
||
URB2403YMD-6WR3 |
24 (9-36) |
40 |
3.3 |
1400/0 |
30/50 |
2500 |
80/82 |
|
URB2405YMD-6WR3 |
5 |
1200/0 |
30/50 |
2200 |
83/85 |
|||
URB2412YMD-6WR3 |
12 |
500/0 |
50/80 |
680 |
87/89 |
|||
URB2415YMD-6WR3 |
15 |
400/0 |
50/80 |
470 |
88/90 |
|||
URB2424YMD-6WR3 |
24 |
250/0 |
50/80 |
220 |
89/91 |
|||
URA2405YMD-6WR3 |
±5 |
±600/0 |
30/50 |
1100 |
83/85 |
|||
URA2412YMD-6WR3 |
±12 |
±250/0 |
50/80 |
330 |
86/88 |
|||
URA2415YMD-6WR3 |
±15 |
±200/0 |
50/80 |
220 |
88/90 |
|||
URA2424YMD-6WR3 |
±24 |
±125/0 |
50/80 |
100 |
89/91 |
|||
URB4803YMD-6WR3 |
48 (18-75) |
80 |
3.3 |
1400/0 |
30/50 |
2500 |
80/82 |
|
URB4805YMD-6WR3 |
5 |
1200/0 |
30/50 |
2200 |
83/85 |
|||
URB4812YMD-6WR3 |
12 |
500/0 |
50/80 |
680 |
87/89 |
|||
URB4815YMD-6WR3 |
15 |
400/0 |
50/80 |
470 |
88/90 |
|||
URB4824YMD-6WR3 |
24 |
250/0 |
50/80 |
220 |
89/91 |
|||
URA4805YMD-6WR3 |
±5 |
±600/0 |
30/50 |
1100 |
83/85 |
|||
URA4812YMD-6WR3 |
±12 |
±250/0 |
50/80 |
330 |
86/88 |
|||
URA4815YMD-6WR3 |
±15 |
±200/0 |
50/80 |
220 |
88/90 |
|||
URA4824YMD-6WR3 |
±24 |
±125/0 |
50/80 |
100 |
89/91 |
|||
URB11003YMD-6WR3 |
110 (40-160) |
180 |
3.3 |
1400/0 |
30/50 |
2500 |
80/82 |
|
URB11005YMD-6WR3 |
5 |
1200/0 |
30/50 |
2200 |
83/85 |
|||
URB11012YMD-6WR3 |
12 |
500/0 |
50/80 |
680 |
87/89 |
|||
URB11015YMD-6WR3 |
15 |
400/0 |
50/80 |
470 |
88/90 |
|||
URB11024YMD-6WR3 |
24 |
250/0 |
50/80 |
220 |
89/91 |
|||
URA11005YMD-6WR3 |
±5 |
±600/0 |
30/50 |
1100 |
83/85 |
|||
URA11012YMD-6WR3 |
±12 |
±250/0 |
50/80 |
330 |
86/88 |
|||
URA11015YMD-6WR3 |
±15 |
±200/0 |
50/80 |
220 |
88/90 |
|||
URA11024YMD-6WR3 |
±24 |
±125/0 |
50/80 |
100 |
89/91 |
|||
Discover: 1. Attributable to restricted home, the above is simply an inventory of typical merchandise. In the event you occur to need merchandise apart from the itemizing, please contact the product sales division of our agency. 2. The utmost capacitive load signifies the utmost capacitive load that could be associated to +Vo or -Vo. If it exceeds this price, the product will likely be unable to start often. |
||||||||